TABLE II. Electrical characteristics.
Rated
Dash
voltage
Minimum insertion loss (dB) in accordance with MIL-STD-220
Cap.
+ 25°C 1/
-55°C, +25°C, and +125°C
-55° and +125°C 1/
no.
(min)
pF
V
V
5
10
20
50
100
200
400
500
1
2
10
5
10
20
50
100
200
400
dc
rms
MHz
MHz
MHz MHz MHz MHz MHz MHz GHz GHz GHz MHz MHz MHz MHz MHz MHz
MHz
2/
0001
200
140
1,500
--
3
13
32
45
58
--
70
70
--
70
--
--
5
15
28
46
--
0002
200
--
1,500
--
5
12
28
45
--
--
68
70
70
--
--
--
5
15
28
--
--
0003
70
--
1,500
5
--
19
--
50
--
65
--
65
--
65
--
--
7
--
32
--
63
0004
70
--
12,000
--
22
30
--
70
--
65
--
--
--
65
--
11
17
--
70
--
63
0005
200
140
3,000
3
12
23
38
50
60
--
--
65
65
65
--
5
10
16
30
48
--
1/ Full-load insertion loss measurements shall be performed at 5, 10 and 20 MHz; all other measurements shall be performed at no-load.
2/ 0 to 400 MHz.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business