MIL-PRF-15733/61G
TABLE III. Electrical characteristics - Continued.
Minimum insertion loss (dB) in accordance with MIL-STD-220. 1/
Dash
Cir-
Rated
Rated
Capac-
Volt-
-55°C and +125°C
number
cuit
voltage
current
itance
age
amps
(min)
drop
V dc Vrms
1
5
10
20
50
100
200
500
1
10
pF
volts
2/
MHz
MHz
MHz
MHz MHz MHz MHz
MHz
GHz
GHz
š
0001 3/
200
140
10
1,500
.1
----
----
----
----
15
28
46
70
70
70
š
0002
200
140
10
1,500
.1
----
----
----
----
15
28
46
70
70
70
š
0003
500
350
25
2,000
.5
----
----
----
----
25
40
59
70
70
70
š
0004 3/
500
350
25
2,000
.5
----
----
----
----
25
40
59
70
70
70
š
0006
200
140
10
1,500
.1
----
----
----
----
16
30
48
70
70
70
š
0007
100
70
10
5,000
.1
----
----
----
----
16
30
48
70
70
70
š
0008
100
70
10
1,000
.1
----
----
----
----
20
35
55
70
70
70
š
0009
70
----
10
12,000
.1
----
8
----
30
----
63
----
----
65
65
š
0011
100
70
10
5,000
.5
----
----
----
----
16
30
----
65
70
70
0013
100
----
10
22,000
.1
8
----
28
----
----
40
43
----
60
60
L2
š
0014
50
----
20
10,000
.5
----
----
18
----
48
63
70
70
70
70
š
0015
500
----
15
2,500
.15
----
----
3
----
----
45
50
----
70
70
š
0016
100
----
10
25,000
.1
----
13
----
27
58
70
----
65
65
65
1/ Insertion loss measurements between 1 MHz and 10 MHz, inclusive, shall be performed at full load.
Insertion loss measurements above 10 MHz shall be performed at no load.
2/ Zero to 400 Hz over the rated temperature range of -55°C to +125°C.
3/ Inactive for new design.
Conformance inspection: In accordance with MIL-PRF-15733 except as follows:
Group A: In accordance with MIL-PRF-15733 for dash numbers 0001 and 0004. Group A inspection for all
other dash numbers shall be in accordance with table IV. Lots having greater than 10 percent rejects shall be
considered reject lots. Reject lots, at the option of the manufacturer, may be reworked and submitted to group
A inspection of table IV.
TABLE IV. Group A inspection.
Test or inspection
Sampling procedure
Voltage conditioning
100%
Dielectric withstanding voltage
100%
Insulation resistance
100%
Voltage drop 1/
100%
Insertion loss (check test)
100%
Radiographic inspection 2/
100%
Visual and mechanical inspection
See MIL-PRF-15733, group A inspection
1/ DC voltage drop/dc resistance test for dc rated filters shall be performed on a
sample basis in accordance with MIL-PRF-15733, group A inspection.
2/ Applicable to dash numbers 0011 and 0016 only.
8