MIL-PRF-15733/61G
Voltage conditioning (conformance inspection only) (applicable to dash numbers 0002, 0003, and 0006
through 0016). The test shall be performed as follows:
Test temperature: +125°C +4°C, -0°C
Test voltage: 1.4 times rated dc voltage.
Test duration: 168 ± 4 hours.
Temperature rise: 25°C maximum except -0014 shall be 40°C maximum.
Dielectric withstanding voltage: In accordance with MIL-PRF-15733 except that the voltage shall be applied
between either terminal and ground (case) for 1 to 5 seconds.
condition C. The following exception shall apply:
Dielectric withstanding voltage: 1.5 times the rated dc voltage applied between either terminal and ground
(case) for 1 to 5 seconds.
Insulation resistance: In accordance with MIL-PRF-15733. The following details and exceptions shall apply:
Test temperature: +25°C ± 3°C.
Test potential: 100 V dc or rated dc voltage, whichever is less.
Points of measurement: Between either terminal and ground (case).
Minimum insulation resistance: 10,000 megohms.
Terminal strength: In accordance with MIL-PRF-15733 and method 211 of MIL-STD-202; test condition A. The
following details shall apply:
Applied force: 5 pounds.
Overload: In accordance with MIL-PRF-15733. The following exception shall apply:
Measurements after test: Insulation resistance only shall be measured at +25°C and shall meet initial
requirements.
Thermal shock and immersion: Not applicable.
Shock (specified pulse): In accordance with MIL-PRF-15733 and method 213 of MIL-STD-202; test condition I.
Vibration, high frequency: In accordance with MIL-PRF-15733 and method 204 of MIL-STD-202; test condition D.
6