TABLE I. Electrical characteristics.
Minimum insertion loss (dB) in accordance with MIL-STD-220 at ±25°C 2/ 3/
Dash
Rated
Voltage
Rated voltage
no.
current
drop
.15
.30
.50
.60
1.0
10
20
40
100
500
1
V dc
V ac
(amps)
(volts)
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
GHz
1/
0001
400
125
10
.5 V rms
24
46
60
65
79
88
88
90
90
90
70
0002
400
125
20
.16 V rms
55
75
75
75
90
90
90
90
90
90
90
0003
400
125
15
.5 V rms
38
58
70
70
80
80
80
80
80
80
80
0004
125
---
20
1.25 V dc
50
58
82
86
90
90
90
90
90
84
84
0005
400
125
1
.5 V rms
60
75
80
80
80
80
80
80
80
80
80
0006
400
125
10
.22 V dc
44
62
75
80
90
85
85
85
85
85
85
1/ DC to 400 Hz.
2/ Full load insertion loss measurements shall be performed at frequencies between 150 kHz to 20 MHz inclusive; all other
measurements shall be performed at no load.
3/ In addition, the following dash numbers shall meet the following no-load insertion loss measurements at the specified frequencies.
Dash no.
.15
.3
.5
.6
1
10
20
MHz
MHz
MHz
MHz
MHz
MHz
MHz
0001
44
60
---
78
90
90
90
0004
58
---
86
---
---
---
---
0006
60
---
88
88
100
---
---
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business