MIL-PRF-15733/43E
Dielectric withstanding voltage: In accordance with MIL-PRF-15733. The following exceptions shall apply:
The test voltage shall be three times the rated dc voltage applied for 1 to 5 seconds.
Barometric pressure (reduced): In accordance with MIL-PRF-15733. The following exceptions shall apply:
Test condition E, Method 105 of MIL-STD-202.
Dielectric withstanding voltage: In accordance with initial requirements, except that the test voltage shall be
120 percent of the rated dc voltage applied for 1 to 5 seconds.
Insulation resistance: In accordance with MIL-PRF-15733. Insulation resistance shall be measured at 25°C
between either terminal and case, and shall be not less than 10,000 megohms.
Insertion loss at +25°C and temperature extremes: In accordance with MIL-PRF-15733 and table I.
Overload: In accordance with MIL-PRF-15733. The following exception shall apply:
Measurements at 25°C after test:
Insulation resistance only shall be measured and shall meet initial requirements.
Terminal strength: In accordance with MIL-PRF-15733 and Method 211, MIL-STD-202; test condition A.
Applied force: 5 pounds.
Salt atmosphere (corrosion): In accordance with MIL-PRF-15733 and Method 101, MIL-STD-202; test condition B.
Thermal shock and immersion: Not applicable.
Shock (specified pulse): In accordance with MIL-PRF-15733 and Method 213, MIL-STD-202; test condition C.
Vibration, high frequency: In accordance with MIL-PRF-15733 and Method 204, MIL-STD-202; test condition C.
The following exceptions shall apply:
Part 2 of the test shall be 20 g's.
Duration shall be 3 hours each in two mutually perpendicular planes.
Moisture resistance: Not applicable.
Life: In accordance with MIL-PRF-15733 and Method 108, MIL-STD-202; test condition D. The following details
and exceptions shall apply:
Test voltage: 2 times rated dc voltage with no load at 125°C for 1,000 hours.
Measurements after test:
Dielectric withstanding voltage initial voltage applied for 1 to 5 seconds and shall meet initial requirements.
Insulation resistance shall be not less than 1,000 megohms.
Capacitance to ground and insertion loss shall be measured and shall meet the initial requirements.