MIL-PRF-15733/43E
TABLE I. Electrical characteristics.
Rated voltage
Minimum insertion loss (dB) in accordance with MIL-STD-220 2/
Dash
Capacitance
no.
pF
+25°C
-55°C,
+125°C
minimum
DC
AC 1/
volts
rms
10
30
100
200
300
1-10
10
30
100
200
300
1-10
volts
MHz
MHz
MHz MHz
MHz
GHz
MHz
MHz
MHz
MHz MHz
GHz
0001
200
140
1500
---
---
---
45
45
45
---
---
---
28
45
45
0002
100
70
1500
---
---
---
50
50
50
---
---
---
28
50
50
0003
500
N/A
2500
12
20
45
---
60
70
4
11
25
---
50
70
1/ DC to 400 Hz.
2/ Full-load insertion loss measurements shall be performed at 10 MHz. Measurements above this frequency shall
be performed at no-load.
REQUIREMENTS:
Design and construction:
Dimensions and configuration: See figure 1.
Case: Metal.
Case and hardware finish: In accordance with MIL-PRF-15733. Pure tin finish is prohibited.
Weight: 2.6 grams, maximum.
Operating temperature range: -55°C to +125°C.
Rated voltage: See table I.
Rated current: 10 amperes maximum.
Voltage drop: 0.10 volts maximum.
Voltage conditioning (conformance inspection only). Voltage conditioning test shall be performed as follows:
Test temperature: 125°C.
Test voltage: 200 percent of the rated dc voltage. Charging current shall not exceed 50 mA.
Current load: Not applicable.
Points of application of test voltage: Between either terminal and case.
Duration of exposure to test voltage: 100 ±4 hours.
Seal: Not applicable.
Capacitance to ground: In accordance with MIL-PRF-15733. The following details shall apply:
Test voltage: 0.5 V rms at 25°C.
Measured capacitance shall be as specified in table I.
Temperature rise: 25°C, maximum.
3