4.7.12 Vibration (see 3.15). Filters shall be tested in accordance with 4.7.12.1 or 4.7.12.2, as specified (see 3.1).
4.7.12.1 Vibration (grades 4 and 5). Filters shall be tested in accordance with method 201, MIL-STD-202. The
following details shall apply:
a.
Tests and measurements prior to vibration: Not applicable.
b.
Method of mounting: Filters shall be rigidly mounted by their normal mounting means.
c.
Electrical load as specified (see 3.1).
d.
Tests and measurements after vibration: Dielectric withstanding voltage and electrical characteristics shall
be measured as specified in 4.7.6 and 4.7.8, respectively. Filters shall then be examined for evidence of
leakage and physical damage.
4.7.12.2 Vibration, high frequency (grades 6, 7, 8, and 9). Filters shall be tested in accordance with method 204,
MIL-STD-202. The following details shall apply:
a.
Method of mounting: Filters shall be rigidly mounted by their normal mounting means.
Electrical load: As specified (see 3.1).
b.
c.
Test condition letter:
(1)
A: For grades 8 and 9.
(2)
B: For grades 6 and 7.
d.
Measurements after test: Dielectric withstanding voltage and electrical characteristics shall be measured
as specified in 4.7.6 and 4.7.8, respectively. Filters shall then be examined for evidence of leakage and
physical damage.
4.7.13 Shock (see 3.16). Filters shall be tested in accordance with 4.7.13.1 or 4.7.13.2, as specified (see 3.1).
4.7.13.1 Shock (specified pulse). Filters shall be tested in accordance with method 213, MIL-STD-202. The
following details and exceptions shall apply:
a.
Mounting: By normal means.
b.
Test condition letter: I.
c.
Measurements after shock: Dielectric withstanding voltage and electrical characteristics shall be measured
as specified in 4.7.6 and 4.7.8, respectively. Filters shall then be examined for evidence of leakage and
physical damage.
4.7.13.2 High-impact shock (when specified, see 3.1). Filters shall be tested in accordance with method 207, MIL-
STD-202. The following details shall apply:
a.
Mounting fixture: Figure 207-5 of method 207.
b.
Measurements after test: Dielectric withstanding voltage and electrical characteristics shall be measured
as specified in 4.7.6 and 4.7.8, respectively. Filters shall then be examined for evidence of leakage and
physical damage.
26
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business