TABLE I. Electrical characteristics.
Product
Maxi-
Capaci-
Maxi-
Maxi-
Dash
Minimum insertion loss (dB) in accordance with MIL-STD-220 1/ 2/
assurance
Cir-
mum
tance
mum
mum
(µF)
number
level
cuit
current
volt-
DC
At +25°C
At -55°C and +125°C
(amps)
+100%
age
resist-
Class
-0%
drop
ance
B
S
100
150
300
1
10
100
1
100
150
300
1
10
100
1
(volts)
(ohms)
kHz
kHz
kHz
MHz
MHz
MHz
GHz
kHz
kHz
kHz
MHz
MHz
MHz
GHz
001, 013
X
X
L1
0.25
0.15
0.375
1.5
22
28
40
60
60
60
70
20
26
38
58
60
60
70
002, 014
X
X
L2
0.25
0.15
0.375
1.5
22
28
40
60
60
60
70
20
26
38
58
60
60
70
š
003, 015
X
X
0.25
0.30
0.375
1.5
34
44
62
80
80
80
80
32
42
60
78
80
80
80
004, 016
X
X
L1
1.0
0.15
0.250
0.25
8
13
24
45
60
60
70
6
11
22
43
60
60
70
005, 017
X
X
L2
1.0
0.15
0.250
0.25
8
13
24
45
60
60
70
6
11
22
43
60
60
70
š
006, 018
X
X
1.0
0.30
0.250
0.25
18
32
50
80
80
80
80
16
30
48
78
80
80
80
007, 019
X
X
L1
3.0
0.15
0.150
0.05
5
8
16
30
60
60
70
3
6
14
28
58
60
70
008, 020
X
X
L2
3.0
0.15
0.150
0.05
5
8
16
30
60
60
70
3
6
14
28
58
60
70
š
009, 021
X
X
3.0
0.30
0.150
0.05
---
---
19
59
80
80
80
---
---
17
57
80
80
80
010, 022
X
X
L1
5.0
0.15
0.075
0.015
5
8
14
26
55
55
70
3
6
12
24
53
55
70
011, 023
X
X
L2
5.0
0.15
0.075
0.015
5
8
14
26
55
55
70
3
6
12
24
53
55
70
š
012, 024
X
X
5.0
0.30
0.075
0.015
---
---
---
51
80
80
80
---
---
---
49
80
80
80
1/ Insertion loss measurements shall be made under full load over the frequency range of 100 kHz to 10 MHz. Insertion loss measurements above this
frequency range shall be under no load.
2/ The insertion loss requirements between any two adjacent specified frequencies shall be that of the lower of the two frequencies in order to accommodate
resonant dips.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business