TABLE I. Electrical characteristics.
Maxi-
Mini-
Maxi-
Maxi-
Product
Cir-
mum
mum
mum
mum
Dash
Minimum insertion loss (dB) in accordance with MIL-STD-220 1/ 2/
assurance
cuit
current
capaci-
volt-
DC
number
level
At +25°C
At -55°C and +125°C
(amps)
tance
age
resist-
Class
(µF)
drop
ance
100
150
300
1
10
100
1
100
150
300
1
10
100
1
B
S
(volts)
(ohms)
kHz
kHz
kHz
MHz
MHz
MHz
GHz
kHz
kHz
kHz
MHz
MHz
MHz
GHz
001, 013
X
X
L1
0.25
0.45
0.375
1.5
30
38
50
60
60
60
70
28
36
48
58
60
60
70
002, 014
X
X
L2
0.25
0.45
0.375
1.5
30
38
50
60
60
60
70
28
36
48
58
60
60
70
š
003, 015
X
X
0.25
0.90
0.375
1.5
54
64
80
80
80
80
80
52
62
78
78
80
80
80
004, 016
X
X
L1
1.0
0.45
0.250
0.25
15
23
34
55
60
60
70
13
21
32
53
60
60
70
005, 017
X
X
L2
1.0
0.45
0.250
0.25
15
23
34
55
60
60
70
13
21
32
53
60
60
70
š
006, 018
X
X
1.0
0.90
0.250
0.25
40
52
70
80
80
80
80
38
50
68
78
80
80
80
007, 019
X
X
L1
3.0
0.45
0.150
0.05
14
18
27
45
60
60
70
12
16
25
43
60
60
70
008, 020
X
X
L2
3.0
0.45
0.150
0.05
14
18
27
45
60
60
70
12
16
25
43
60
60
70
š
009, 021
X
X
3.0
0.90
0.150
0.05
---
25
51
80
80
80
80
---
23
49
78
80
80
80
010, 022
X
X
L1
5.0
0.45
0.075
0.015
14
17
24
36
60
60
70
12
15
22
34
60
60
70
011, 023
X
X
L2
5.0
0.45
0.075
0.015
14
17
24
36
60
60
70
12
15
22
34
60
60
70
š
012, 024
X
X
5.0
0.90
0.075
0.015
---
---
38
75
80
80
80
---
---
36
73
80
80
80
1/ Insertion loss measurements shall be made under full load over the frequency range of 100 kHz to 10 MHz. Insertion loss measurements above this
frequency range shall be made under no load.
2/ The insertion loss requirements between any two adjacent specified frequencies shall be that of the lower of the two frequencies in order to
accommodate resonant dips.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business