MIL-PRF-15733/75A
TABLE I. Electrical characteristics.
Minimum insertion loss (dB)
in accordance with MIL-STD-220 1/
Rated
Dash
Number
(each circuit)
number
of
current
At +25°C
(amps)
circuits
(each
150
300
500
1
10
50
100
1
10
circuit)
kHz
kHz
kHz
MHz
MHz
MHz
MHz
GHz
GHz
0001
2
3
60
80
80
80
80
80
80
80
80
0002
2
3
80
80
80
80
80
80
80
80
80
0003
2
5
60
80
80
80
80
80
80
80
80
0004
2
5
80
80
80
80
80
80
80
80
80
0005
2
10
60
80
80
80
80
80
80
80
80
0006
2
10
80
80
80
80
80
80
80
80
80
0006A
2
10
80
80
80
80
80
80
80
80
80
0007
2
20
60
80
80
80
80
80
80
80
80
0008
2
30
60
80
80
80
80
80
80
80
80
0009
2
50
60
80
80
80
80
80
80
80
80
0010
3
3
60
80
80
80
80
80
80
80
80
0011
3
3
80
80
80
80
80
80
80
80
80
0012
3
5
60
80
80
80
80
80
80
80
80
0013
3
5
80
80
80
80
80
80
80
80
80
0014
3
10
60
80
80
80
80
80
80
80
80
0015
3
10
80
80
80
80
80
80
80
80
80
0016
3
20
60
80
80
80
80
80
80
80
80
0017
3
30
60
80
80
80
80
80
80
80
80
0018
3
50
60
80
80
80
80
80
80
80
80
1/ Full-load insertion loss measurements shall be performed over the frequency range of 150 kHz to 10 MHz, inclusive.
Measurements below or above this frequency range shall be performed at no-load.