MIL-PRF-15733/63A
Shock (specified pulse): In accordance with MIL-PRF-15733 and Method 213, MIL-STD-202; test condition I.
Vibration, high frequency: In accordance with MIL-PRF-15733 and Method 204, MIL-STD-202; test condition D.
Moisture resistance: In accordance with MIL-PRF-15733. The following exception shall apply:
Insulation resistance shall be not less than 1 Gohm after the 24-hour drying period.
Life: In accordance with MIL-PRF-15733 and Method 108, MIL-STD-202; test condition D. The following
exception shall apply:
Insulation resistance shall be not less than 1 Gohm after the test.
TABLE I. Insertion loss versus frequency.
Minimum insertion loss (dB) at +25°C
Dash
number
50 MHz
100 MHz
200 MHz
500 MHz
1-10 GHz
70
0001
50
65
65
65
Qualification inspection: Qualification inspection is not applicable to this document.
Conformance inspection: Group A inspection only shall be performed. This does not relieve the product from
conforming to the group C requirements.
Part or Identifying Number (PIN): M15733/63-0001.
Supersession data: Filters in this specification supersedes filters in MIL-F-15733/32(USAF) as follows:
MIL-F-15733/32(USAF)
MIL-PRF-15733/63
PIN
PIN
M15733/32-0001
M15733/63-0001
NOTES:
Referenced documents. In addition to MIL-PRF-15733, this specification sheet references the following
documents.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-202
Test Method Standard, Electronic and Electrical Component Parts
(Government documents are available on line at https://assist.daps.dla.mil/quicksearch or www.dodssp.daps.mil or
from the Standardization Document Order Desk, 700 Robbins Avenue 4D, Philadelphia, PA 19111-5094).
Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to
the previous issue due to the extent of the changes.