MIL-PRF-15733/59B
FIGURE 2. Voltage conditioning test circuit.
VERIFICATION
Qualification inspection: Requirements of this specification sheet not currently required in MIL-PRF-15733 shall be
included in qualification inspection as group VI (see table II).
TABLE II. Qualification inspection. 1/
Examination or test
Number of samples
Number of defectives
to be inspected
allowed
Group V
Transient voltage
4
0
Inrush transients
4
*
1/ This table is an addition to table III (qualification inspection) of MIL-PRF-15733.
Conformance inspection: Conformance inspection shall be as specified in MIL-PRF-15733 except group A
inspection shall be as specified in table III of this specification sheet, in the order shown. Lots that have greater
than 5 percent rejects shall be considered reject lots. Reject lots may, at the option of the supplier, be resubmitted
to 100 percent group A inspection; however, resubmitted lots which have greater than 2 percent rejects shall be
rejected and may not be resubmitted for reinspection.
Group C inspection shall be as specified in MIL-PRF-15733 and shall include the tests specified in table IV of this
specification sheet.
7