MIL-PRF-15733/55F
TABLE II. Insertion-loss (dB) (full load) versus frequency (MHz).
Minimum insertion loss full load in accordance with MIL-STD-220 at +25°C
Dash
number
0.15
0.3
0.6
1
10
20
MHz
MHz
MHz
MHz
MHz
MHz
0001
40
58
76
80
80
80
0003
.15 MHz to 10 GHz
60
TABLE III. Insertion-loss (dB) (no load) versus frequency (MHz).
Minimum insertion loss no load in accordance with MIL-STD-220 at +25°C
Dash
number
0.15
0.3
0.5
1
10
20
40-500
100
400
1000
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
0001
54
73
85
94
84
84
67
N/A
N/A
64
0002
54
N/A
85
94
84
N/A
N/A
80
80
N/A
*
TABLE IV. Substitution Data
Inactive PIN
Superseding PIN
M15733/73-0042
M15733/55-0001
M15733/73-0045
M15733/55-0002
M15733/73-0039 or -0040
M15733/55-0003
Referenced documents. In addition to MIL-PRF-15733, this document also references the following:
*
*
Changes from previous issue. The margins of this specification sheet are marked with asterisks to indicate where
changes from the previous issue were made. This was done as a convenience only and the Government assumes
no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate
the requirements of this document based on the entire content irrespective of the marginal notations and
relationship to the last previous issue.
Custodians:
Preparing activity:
Army - CR
DLA - CC
Navy - EC
Air Force - 85
(Project 5915-2008-019)
DLA - CC
Review activities:
Navy - SH
Air Force - 99
*
NOTE: The activities listed above were interested in this document as of the date of this document. Since
organizations and responsibilities can change, you should verify the currency of the information above using the
ASSIST Online database at https://assist.daps.dla.mil.
4