MIL-PRF-15733/33D
Shock (specified pulse): In accordance with MIL-PRF-15733 and Method 213, MIL-STD-202; test condition I.
Vibration, high frequency: In accordance with MIL-PRF-15733 and Method 204, MIL-STD-202; test condition D.
Moisture resistance: In accordance with MIL-PRF-15733. The following details and exceptions shall apply:
Loading voltage: Not applicable.
Polarization voltage: Not applicable.
Measurements after 24-hour drying period, at a temperature not to exceed +85°C, and a relative humidity of
50 percent.
Insulation resistance shall be not less than 1 G ohm.
Life: In accordance with MIL-PRF-15733 and Method 108, MIL-STD-202; test condition D. The following
exceptions shall apply:
Measurements after test:
Insulation resistance shall be not less than 1 G ohm.
Marking: Filters shall not be marked. Full marking in accordance with MIL-PRF-15733, shall be marked on the
unit package.
Part or Identifying Number (PIN): M15733/33-(dash number from table I).
Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to
the previous issue due to the extensiveness of the changes.
Custodians:
Preparing activity:
Army - CR
DLA - CC
Navy - EC
Air Force - 11
(Project 5915-0415)
DLA - CC
Review activities:
Army AT, AV
Navy - AS, CG, MC, OS, SH
Air Force - 19, 99