TABLE I. Electrical characteristics.
Dash
Circuit
Maximum
Maximum
Minimum full-load insertion loss (dB) in accordance with MIL-STD-220 at +25°C 2/ 3/ 4/
no.
config-
rated
voltage
uration
current
drop volts
(amperes)
dc and ac
0.15
0.30
0.60
1
10
20
40
100
400
500
1,000
(rms)
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
L2
3.0
0.5
30
43
53
60
60
60
60
60
60
60
60
0020
L1
3.0
0.5
40
53
60
60
60
60
60
60
60
60
60
0021
L2
3.0
0.5
40
53
60
60
60
60
60
60
60
60
60
0022
L1
0023
5.0
0.5
30
43
53
60
60
60
60
60
60
60
60
L2
0024
5.0
0.5
30
43
53
60
60
60
60
60
60
60
60
L1
5.0
0.5
40
53
60
60
60
60
60
60
60
60
60
0025
L2
5.0
0.5
40
53
60
60
60
60
60
60
60
60
60
0026
0027
T
0.5
2.5
25
35
45
50
70
70
70
70
70
70
70
0028
T
0.5
2.5
37
47
53
57
70
70
70
70
70
70
70
0029
T
1.0
2.5
25
35
45
50
70
70
70
70
70
70
70
0030
T
1.0
2.5
37
47
53
57
70
70
70
70
70
70
70
0031
T
3.0
1.5
25
35
45
50
70
70
70
70
70
70
70
0032
T
3.0
1.5
37
47
53
57
70
70
70
70
70
70
70
0033
T
5.0
1.0
25
35
45
50
70
70
70
70
70
70
70
0034
T
5.0
1.0
37
47
53
57
70
70
70
70
70
70
70
0035
T
10.0
0.5
25
35
45
50
70
70
70
70
70
70
70
0036
T
10.0
0.5
37
47
53
57
70
70
70
70
70
70
70
0037
T
20.0
0.5
25
35
45
50
70
70
70
70
70
70
70
0038
T
20.0
0.5
37
47
53
57
70
70
70
70
70
70
70
0039
T
30.0
0.5
25
35
45
50
70
70
70
70
70
70
70
0040
T
50.0
0.5
25
35
45
50
70
70
70
70
70
70
70
1/ Maximum operating temperature of +85°C.
2/ Dash number 0004 shall also meet the following no-load insertion requirements.
0.15 MHz
0.5 MHz
1 MHz
10 MHz
53 dB
86 dB
100 dB
90 dB
3/ For dash number 0005 through 0010, all insertion loss measurements shall be performed at no-load.
4/ Unless otherwise specified (see 2/ and 3/), full load insertion-loss measurements shall be performed from 0.15 MHz to 20MHz.
Insertion-loss measurements above 20 MHz shall be performed at no-load.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business