MIL-F-15733/53C
REQUIREMENTS:
Dimensions and configuration: See figure and table 1.
Case: Metal.
Case and hardware finish: In accordance with MIL-PRF-15733. Pure tin finish is prohibited.
Terminals: Threaded stud.
Operating temperature range: -55°C to +125°C.
Rated voltage: (over the rated temperature range of -55° to +125°C): See table II.
Rated current: 20 amperes dc.
Insertion loss: In accordance with MIL-PRF-15733 and table II.
Seal: In accordance with MIL-PRF-15733.
Temperature rise: 25°C, maximum.
Dielectric withstanding voltage: In accordance with MIL-PRF-15733 except the test voltage shall be two times the
rated voltage applied between either terminal and case.
Insulation resistance: In accordance with MIL-PRF-15733. Insulation resistance measured at 25°C between
either terminal and the case shall be at least 550 megohms.
Voltage drop: 1 percent of rated voltage, maximum.
Terminal strength: In accordance with MIL-PRF-15733 and Method 211, MIL-STD-202; test condition E.
Applied force: 14 pounds.
Flashpoint of impregnant or potting compound: In accordance with MIL-PRF-15733.
Salt atmosphere (corrosion): In accordance with MIL-PRF-15733 and Method 101, MIL-STD-202; test condition A.
Shock (specified pulse): In accordance with MIL-PRF-15733 and Method 213, MIL-STD-202; test condition I. The
following exceptions shall apply:
Mounting: Filters shall be rigidly mounted by the body.
Insertion loss test: Not applicable.
Vibration, high frequency: In accordance with MIL-PRF-15733 and Method 204, MIL-STD-202; test condition B.
The following exception shall apply:
Electrical current load shall not be applied to filters during the vibration test
Life: In accordance with MIL-PRF-15733 and method 108, MIL-STD-202; test condition B.