MIL-PRF-15733/74B
TABLE I. Electrical characteristics - Continued.
Minimum insertion loss (dB)
Rated
in accordance with MIL-STD-220 1/
current
Dash
Circuit
At +25°C
(amps)
number
diagram
ac (rms)
14
20
50
150
300
600
1
10
100
1
or dc
kHz
kHz
kHz
kHz
kHz
kHz
MHz
MHz
MHz
GHz
Pi
0037
3.0
---
---
---
80
80
80
80
80
80
80
Pi
0038
5.0
---
---
---
40
60
75
80
80
80
80
Pi
0039
5.0
---
---
---
60
80
80
80
80
80
80
Pi
0040
5.0
---
---
---
80
80
80
80
80
80
80
Pi
0041
10.0
---
---
---
40
60
75
80
80
80
80
Pi
0042
10.0
---
---
---
60
80
80
80
80
80
80
Pi
0043
10.0
---
---
---
80
80
80
80
80
80
80
Pi
0044
20.0
---
---
---
40
60
75
80
80
80
80
Pi
0045
20.0
---
---
---
60
80
80
80
80
80
80
Pi
0046
30.0
---
---
---
40
60
75
80
80
80
80
Pi
0047
50.0
---
---
---
40
60
75
80
80
80
80
T
0048
.5
---
---
---
50
65
70
70
70
70
70
T
0049
.5
20
28
50
60
60
60
60
70
70
70
T
0050
1.0
---
---
---
30
50
60
70
70
70
70
T
0051
1.0
20
28
50
60
60
60
60
70
70
70
T
0052
3.0
---
---
---
25
40
60
70
70
70
70
T
0053
3.0
20
28
50
60
60
60
60
70
70
70
T
0054
5.0
---
---
---
25
35
50
60
70
70
70
T
0055
5.0
15
18
28
37
45
53
58
70
70
70
T
0056
10.0
---
---
---
25
35
45
50
70
70
70
T
0057
10.0
15
18
28
37
45
53
58
70
70
70
T
0058
20.0
---
---
---
25
35
45
50
70
70
70
T
0059
20.0
15
18
28
37
43
50
58
70
70
70
T
0060
30.0
---
---
---
25
35
45
50
70
70
70
T
0061
50.0
---
---
---
25
35
45
50
70
70
70
1/ Full-load insertion loss measurements shall be performed over the frequency range of 100 kHz to 20 MHz inclusive.
Measurements below or above this frequency range shall be performed at no-load.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.