MIL-PRF-15733/38L
Terminal strength: In accordance with MIL-PRF-15733 and method 211, MIL-STD-202; test condition A (pull):
Applied force: 5 pounds.
Salt atmosphere (corrosion): In accordance with MIL-PRF-15733 and method 101, MIL-STD-202; test condition A.
Shock (specified pulse): In accordance with MIL-PRF-15733 and method 213, MIL-STD-202; test condition I (100g).
Vibration, high frequency: In accordance with MIL-PRF-15733 and method 204, MIL-STD-202; test condition D (20g).
Qualification inspection: Test condition D (1,000 hours).
Group C inspection:
Dash numbers
Test condition
0001, 0002, 0004 through 0010
B (250 hours)
0003
D (1,000 hours)
Part or Identifying Number (PIN): M15733/38- (dash number from table I).
Marking: Marking shall be as follows:
For dash numbers 0001, 0002, and 0004 through 0010, the filter shall be marked with the following minimum
information:
a. Military PIN.
b. Source code.
c. Date code.
d. Terminal identification.
Full marking in accordance with MIL-PRF-15733 shall be marked on the unit package. For dash number 0003,
the filter shall be marked with full marking in accordance with MIL-PRF-15733.
*
Extension of qualification:
Initial qualification to MIL-PRF-15733/38 may be granted based on qualification to MIL-PRF-28861/1 or /3 or
MIL-PRF-15733/49 to MIL-PRF-15733/38 is permissible under the following provisions:
a. The MIL-PRF-15733/38 part uses the same design and dielectric characteristics as the part upon which
extension of qualification is based.
electrical characteristics of the MIL-PRF-15733/38 parts are satisfied.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business