MIL-F-15733/48G
Insulation resistance: In accordance with MIL-PRF-15733. The following details and exceptions shall apply:
Test potential: 50 V dc.
Insulation resistance minimum
Dash number
700 Megohms at +25°C
0001
100 Megohms at +25°C
0002 through 0005
70 Megohms at +125°C
0001
Voltage drop: See table I.
Terminal strength: In accordance with MIL-PRF-15733 and Method 211, MIL-STD-202; test condition A (pull).
Force: 5 pounds.
Salt atmosphere (corrosion): In accordance with MIL-PRF-15733 and Method 101, MIL-STD-202 and the
following:
Test condition
Dash number
B
0001 and 0002
A
0003 through 0005
Shock (specified pulse): In accordance with MIL-PRF-15733 and Method 213, MIL-STD-202 and the following:
Test condition
Dash number
I
0001 and 0002
A
0003 through 0005
Vibration, high frequency: In accordance with MIL-PRF-15733 and Method 204, MIL-STD-202; test condition D.
Radiographic inspection: (applicable to dash number 0001 only). The radiographic inspection shall be conducted
as follows:
Filters shall be X-rayed in one plane at 90 degree rotation (perpendicular to the filter longitudinal axis). Any
evidence of poor capacitor mounting or uneven soldering of capacitor to case shall be cause for rejection.
Rejected units shall be dissected and examined for poor workmanship or uneven soldering. Any defects noted
shall require corrective action prior to acceptance of any future lots. Magnification during visual examination
shall be two power, minimum. Unless otherwise specified, one radiograph shall be taken of each unit. Filters
shall be positioned to yield a longitudinal image of the body.
Moisture resistance: In accordance with MIL-PRF-15733 except after the 24 hour drying period, insulation
resistance shall be not less than 50 Megohms.
Life: In accordance with MIL-PRF-15733 and Method 108, MIL-STD-202. Test condition D (1,000 hours) for
qualification inspection; test condition B (250 hours) for group C inspection.
Conformance inspection: In accordance with MIL-PRF-15733 except as follows:
Group A: In accordance with MIL-PRF-15733 for dash numbers 0002 through 0005. Group A
inspection for dash number 0001 shall be in accordance with table II. Lots having greater than
10 percent rejects shall be considered reject lots. Reject lots, at the option of the manufacturer, may
be reworked and submitted to 100 percent, group A inspection of table II.